WELL05-001-10193Seltzer LD
09-379HC
PDC ENERGY INC
69175
PR
5/16/2022
WATTENBERG
90750
ADAMS  001
NWNE 4 1S67W 6
320515
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 2036 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
Click for SpecificsFull10/21/202411/4/2024 2Down to Zero--0No Flow644644NoNoNoAnnual Test.  2 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull12/8/202312/11/2023Flowing0No Flow--0No Flow883883NoNoNoAnnual Test. 0 PSI, with no pressure or flow observed for the entire 30-minute test. PDC will monitor pressure and re-test according to bradenhead policy.
403100587Form 177/7/20227/11/2022FLOWING0WHISPER GAS0 NO FLOW 22982297No----Test after DOFP. Whisper on open for 5 seconds and died. No flow for remainder of test.
402922057Form 171/9/20221/10/2022SHUT-IN0NO FLOW NONE0 NO FLOW 00No----Test prior to toe prep/frac. Vacuum on open for 1 minute and 45 seconds.
402811869Form 179/9/20219/15/2021SHUT-IN--NO FLOW NONE0 NO FLOW ----No----Test per NTO. DUC well. Vacuum on open for 2 minutes.