Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-001-10092B-Farm LD
18-036HN
PDC ENERGY INC
69175
PR
12/1/2022
WATTENBERG
90750
ADAMS  001
NENW 7 1S67W 6
452914
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1721 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
403753912Form 174/12/20244/15/2024PLUNGER LIFT38DOWN TO 0 WATER AND GAS0 CONTINUOUS 419440No----Remediation follow up test. 38 PSI water and gas flow blew down to 0 PSI within first few seconds of test. Fluid continued to trickle until 16 minute mark and dripped for remainder of test, ~1 quart total fluid. PDC will monitor pressure and re-test according to bradenhead policy.
403416013Form 175/29/20235/30/2023PLUNGER LIFT12CONTINUOUS GAS0 NO FLOW 418419No----Abatement system follow up test. 12 PSI gas flow blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
403263444Form 1712/15/202212/16/2022SHUT-IN52CONTINUOUS WATER AND GAS0 CONTINUOUS 9696Yes----Automation Alert follow-up test. 52 PSI gas and water blew down to 0 PSI in 5 minutes. Steady trickle started 30 seconds after open and lasted 1.5 minutes, steady drip for remainder of test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
403204499Form 1710/20/202210/21/2022SHUT-IN60DOWN TO 0 WATER AND GAS0 CONTINUOUS 339339Yes----Engineering Ad Hoc test. 60 PSI gas and water flow blew down to 0 PSI within first few seconds of test through 1/2" needle valve. Water continued for entire test, 1/2 gallon total fluid. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
Click for SpecificsLight10/18/202110/25/2021Plunger Lift7 --0 323324NoNoNoTest per NTO. Puff on open, died instantly. No flow for remainder of test.
Click for SpecificsLight11/30/202012/7/2020Flowing13 --0No Flow325324NoNoNoTest per NTO. Whisper for 2 seconds at open then dead.
402137750Form 178/5/20198/8/2019SHUT-IN3NO FLOW --0 NO FLOW 957957No----Test Per NTO. BH dead.
401628910Form 175/1/20185/3/2018FLOWING2NO FLOW --0 NO FLOW 16281628No----Test taken withing 30 days of DOFP. Bradenhead dead.
401551358Form 172/24/20182/28/2018SHUT-IN0NO FLOW --0 NO FLOW 00No----