Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-001-10082Prairie LE
31-369HC
PDC ENERGY INC
69175
PR
8/15/2021
WATTENBERG
90750
BRIGHTON/ADAMS  001
SWSW 20 1S66W 6
450942
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 2034 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
Click for SpecificsFull11/14/202511/24/2025 45Down to Zero--0No Flow415421NoNoNoAnnual Test.  45 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
404293223Form 177/17/20257/24/2025GAS LIFT29CONTINUOUS GAS0 NO FLOW 435446No----Remediation follow up test. 29 PSI whisper blew down to 0 PSI within five minutes of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
403764234Form 174/15/20244/22/2024PLUNGER LIFT38DOWN TO 0 GAS0 NO FLOW 574575No----Remediation follow up test. 38 PSI gas flow blew down to 0 PSI within first 100 seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403539580Form 179/21/20239/25/2023PLUNGER LIFT53CONTINUOUS GAS0 NO FLOW 699701Yes----Automation follow-up test. 53 PSI gas flow blew down to 0 PSI in 5 minutes. No flow or pressure for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull8/1/20238/14/2023Shut In4Down to Zero--0Down to Zero885885NoNoNoAnnual Test. 4 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull10/10/202211/8/2022Flowing0Down to Zero--0Down to Zero965965NoNoneNone 
402835804Form 1710/7/202110/8/2021FLOWING0WHISPER GAS0 NO FLOW 12601259No----Test after DOFP. Whisper on open for 8 seconds and died. No flow for remainder of test.
402737422Form 176/23/20217/2/2021SHUT-IN0NO FLOW NONE0 NO FLOW 00No----Test prior to toe prep/frac. Vacuum on open for 85 seconds.