Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-001-10078Prairie LE
17-021HN
PDC ENERGY INC
69175
PR
8/15/2021
WATTENBERG
90750
BRIGHTON/ADAMS  001
SWSW 20 1S66W 6
450942
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 2031 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
Click for SpecificsFull11/13/202511/17/2025 37Continuous--0No Flow342343NoNoNo Annual Test.  37 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
404329389Form 178/7/20258/25/2025GAS LIFT49CONTINUOUS GAS0 NO FLOW 270270No----Remediation follow up test. 49 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull4/15/20244/30/2024 43Down to Zero--0Down to Zero378378NoNoNo 
403495492Form 178/1/20238/14/2023SHUT-IN20CONTINUOUS GAS0 NO FLOW 552552No----Abatement system follow up test. 20 PSI gas flow blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
403265818Form 1712/19/202212/20/2022GAS LIFT51CONTINUOUS GAS0 WHISPER 657665Yes----Automation Alert follow-up. 51 PSI continuous whisper gas blew down to 0 PSI within thirty minutes. PDC collected a sample 11/23/2022. PDC will continue to monitor monthly.
403193390Form 1710/10/202210/11/2022FLOWING58DOWN TO 0 GAS0 NO FLOW 567567Yes----Automation Alert test. 58 PSI gas flow blew down to 0 PSI in five minutes through 1/2" needle valve. No flow or pressure for the remainder of the test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
402835709Form 1710/7/202110/8/2021FLOWING0WHISPER GAS0 NO FLOW 12071207No----Test after DOFP. Whisper on open for 5 seconds and died. No flow for remainder of test.
402726133Form 176/21/20216/22/2021SHUT-IN0NO FLOW NONE0 NO FLOW 00No----Test prior to toe prep/frac. Vacuum on open for 28 seconds.