Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-001-10076Prairie LE
18-031HC
PDC ENERGY INC
69175
PR
8/15/2021
WATTENBERG
90750
BRIGHTON/ADAMS  001
SWSW 20 1S66W 6
450942
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 2061 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404439411Form 1711/13/202511/17/2025GAS LIFT81CONTINUOUS WATER AND GAS0 DOWN TO 0 466458No----Annual Test. 81 PSI continuous water and gas blew down to 0 PSI within thirty minutes of test. Gas and Water observed for entire test. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
404329413Form 178/7/20258/25/2025GAS LIFT63CONTINUOUS GAS0 NO FLOW 487481No----Remediation follow up test. 63 PSI gas blew down to 0 PSI within five minutes of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
403764221Form 174/15/20244/22/2024PLUNGER LIFT33DOWN TO 0 WATER AND MUD0 NO FLOW 574581No----Remediation follow up test. 33 PSI water and mud blew down to 0 PSI within first 3 minutes of test, ~2.5 gallons total. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403658464Form 171/17/20241/18/2024SHUT-IN28CONTINUOUS GAS0 CONTINUOUS 631631No----Abatement system follow up test. 28 PSI gas flow blew down to 0 PSI within 25 seconds. White foamy hydrate started after 1 minute and trickled for remainder of test, ~1 quart total. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull8/1/20238/14/2023Plunger Lift6Down to Zero--0Down to Zero765764NoNoNoAnnual Test. 6 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403092394Form 176/27/20226/29/2022FLOWING67DOWN TO 0 MUD0 CONTINUOUS 11931192Yes----Test after pressure discovery. Mud on open, collected 40mL production and BH sample. Produced ~1 gallon and flow died to drip/trickle. Drips for remainder of test. Produced ~1.25 gallons total.
402835796Form 1710/7/202110/8/2021FLOWING1WHISPER GAS0 NO FLOW 12681267No----Test after DOFP. Whisper on open for 5 seconds and died. No flow for remainder of test.
402737433Form 176/23/20217/2/2021SHUT-IN0NO FLOW NONE0 NO FLOW 00No----Test prior to toe prep/frac. Vacuum on open for 98 seconds.