Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-001-10072Prairie LE
17-015HN
PDC ENERGY INC
69175
PR
9/3/2021
WATTENBERG
90750
BRIGHTON/ADAMS  001
SESW 20 1S66W 6
450942
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 2038 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404449005Form 1711/13/202511/24/2025GAS LIFT53CONTINUOUS GAS0 NO FLOW 296286No----Annual Test. 53 PSI blew down to 0 PSI within five minutes of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
404293215Form 177/17/20257/24/2025GAS LIFT22CONTINUOUS GAS0 NO FLOW 300300No----Remediation follow up test. 22 PSI whisper blew down to 0 PSI within five minutes of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
403947698Form 1710/2/202410/7/2024PLUNGER LIFT52DOWN TO 0 GAS0 NO FLOW 256254No----Ad hoc test. 52 PSI gas flow blew down to 0 PSI within first 5 minutes of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403764178Form 174/15/20244/22/2024PLUNGER LIFT38DOWN TO 0 GAS0 NO FLOW 337336No----Remediation follow up test. 38 PSI gas blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull8/1/20238/14/2023Shut In36Down to Zero--0Down to Zero464464NoNoNoAnnual Test. 36 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull10/10/202211/8/2022Gas Lift0Down to Zero--0Down to Zero517516NoNoneNone 
402835781Form 1710/7/202110/8/2021FLOWING0NO FLOW NONE0 NO FLOW 11481148No----Test after DOFP. BH dead.
402737405Form 176/23/20217/2/2021SHUT-IN0NO FLOW NONE0 NO FLOW 00No----Test prior to toe prep/frac. Vacuum on open for 44 seconds.