Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-001-10066Prairie LE
17-016HC
PDC ENERGY INC
69175
PR
8/1/2025
WATTENBERG
90750
BRIGHTON/ADAMS  001
SWSW 20 1S66W 6
450942
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 2045 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
Click for SpecificsFull11/14/202511/24/2025 41Down to Zero--0No Flow448448NoNoNoAnnual Test.  41 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
404198355Form 174/28/20255/9/2025GAS LIFT44CONTINUOUS WATER AND GAS1 WHISPER 288283No----Remediation follow up test. 44 PSI gas and water, blew down to 0 within first few seconds, water continued for entire test, ~2 gal. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull4/15/20244/30/2024 43Down to Zero--0Down to Zero361377NoNoNo 
Click for SpecificsFull8/1/20238/14/2023Shut In29Down to Zero--0Down to Zero584584NoNoNoAnnual Test. 29 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403298130Form 171/19/20231/23/2023GAS LIFT57CONTINUOUS GAS0 NO FLOW 701700Yes----Automation Alert follow-up test. 57 PSI gas flow blew down to 0 PSI within first few seconds of test through 1/2" needle valve. 1 pint of water at 3 minute mark. No pressure or flow observed for the remainder of the test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
Click for SpecificsFull10/10/202211/8/2022Flowing37Down to Zero--0Down to Zero972973NoNoneNone 
402835745Form 1710/7/202110/8/2021FLOWING10DOWN TO 0 GAS0 NO FLOW 14061406No----Test after DOFP. Gas on open for 4 minutes and died. No flow for remainder of test.
402737414Form 176/23/20217/2/2021SHUT-IN0NO FLOW NONE0 NO FLOW 00No----Test prior to toe prep/frac. Vacuum on open for 1 minute and 30 seconds.