Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-001-09965Seltzer LD
21-033HC
PDC ENERGY INC
69175
PR
4/1/2022
WATTENBERG
90750
ADAMS  001
NWNE 4 1S67W 6
320515
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1738 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404196821Form 174/22/20255/8/2025GAS LIFT12CONTINUOUS GAS1 WHISPER 380380No----Remediation follow up test. 12 PSI continuous gas flow blew down to 1 PSI within thirty minutes. Whisper gas observed for entire test. Operator will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull10/22/202411/4/2024 19Down to Zero--0No Flow390390NoNoNoAnnual Test.  19 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull12/8/202312/11/2023Plunger Lift8Down to Zero--0No Flow448492NoNoNoAnnual Test. 8 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403200033Form 1710/17/202210/18/2022FLOWING4DOWN TO 0 GAS0 NO FLOW 703703No----Remediation follow-up. Test after displacement and buildup since 9/29/2022. Gaseous on open, whisper for 10 seconds and died. No flow for remainder of test. PDC will submit sundry with bradenhead details if needed as soon as possible. PDC will continue to monitor monthly.
403022103Form 174/12/20224/20/2022FLOWING77DOWN TO 0 GAS0 NO FLOW 910909YesYes--Test per NTO. Gas at open for 1 second. BH and production sample collected. Gas for one more second then died. No flow for remainder.
402822672Form 179/21/20219/25/2021SHUT-IN13DOWN TO 0 GAS0 NO FLOW 894897No----Test per NTO. Well shut in due to site ESD. Gas for 2 seconds then dead for remainder of test.
Click for SpecificsLight10/22/202011/9/2020 3 --0No Flow11561172NoNoNo 
401966029Form 173/7/20193/8/2019FLOWING0NO FLOW --0 NO FLOW 24252417No----Test after DOFP. Bradenhead dead.
401877009Form 1712/14/201812/17/2018SHUT-IN0NO FLOW --0 NO FLOW 00No----Test prior to toe prep/frac