WELL05-001-09960Seltzer LD
21-036HN
PDC ENERGY INC
69175
PR
6/3/2022
WATTENBERG
90750
ADAMS  001
NWNE 4 1S67W 6
320515
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 2036 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404098672Form 172/6/20252/18/2025PLUNGER LIFT56CONTINUOUS GAS AND LIQUID HYDROCARBON1 WHISPER 437440No----Engineering Ad Hoc test. 56 PSI gas and liquid hydrocarbon blew down to 1 PSI in thirty minutes. Gas and oil substance present for entire test. Operator will schedule a sampling event and submit results via form 43. Operator will continue to monitor monthly.
403977120Form 1710/28/202410/31/2024PLUNGER LIFT64CONTINUOUS LIQUID HYDROCARBON0 CONTINUOUS 459442No----Ad hoc test. 64 PSI liquid flow blew down to 0 PSI in seconds, liquid continued to trickle for entire test, ~0.75 gallons total fluid. PDC will monitor pressure and re-test according to bradenhead policy.
403969591Form 1710/23/202410/24/2024PLUNGER LIFT64CONTINUOUS GAS AND LIQUID HYDROCARBON60 CONTINUOUS 446445No----Annual Test. 64 PSI continuous gas and fluid blew down to 60 PSI in 30 minutes, ~10 gallons muddy oil total fluid. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
403901264Form 178/16/20248/26/2024 57CONTINUOUS LIQUID HYDROCARBON0 NO FLOW 485484No----Engineering Ad Hoc test. 57 PSI blew down to 0 PSI within five minutes of test. No pressure or flow observed for the remainder of the test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
Click for SpecificsFull12/8/202312/11/2023Plunger Lift22Down to Zero--0No Flow553558NoNoNoAnnual Test. 22 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403100628Form 177/7/20227/11/2022FLOWING16DOWN TO 0 GAS0 NO FLOW 19911991No----Test after DOFP. Gaseous on open for 45 seconds and died. No flow for remainder of test.
402922099Form 171/9/20221/10/2022SHUT-IN0NO FLOW NONE0 NO FLOW 00No----Test prior to toe prep/frac. Vacuum on open for 20 seconds.