404098672 | Form 17 | 2/6/2025 | 2/18/2025 | PLUNGER LIFT | 56 | CONTINUOUS | GAS AND LIQUID HYDROCARBON | 1 | WHISPER | 437 | 440 | No | -- | -- | Engineering Ad Hoc test. 56 PSI gas and liquid hydrocarbon blew down to 1 PSI in thirty minutes. Gas and oil substance present for entire test. Operator will schedule a sampling event and submit results via form 43. Operator will continue to monitor monthly. |
403977120 | Form 17 | 10/28/2024 | 10/31/2024 | PLUNGER LIFT | 64 | CONTINUOUS | LIQUID HYDROCARBON | 0 | CONTINUOUS | 459 | 442 | No | -- | -- | Ad hoc test. 64 PSI liquid flow blew down to 0 PSI in seconds, liquid continued to trickle for entire test, ~0.75 gallons total fluid. PDC will monitor pressure and re-test according to bradenhead policy. |
403969591 | Form 17 | 10/23/2024 | 10/24/2024 | PLUNGER LIFT | 64 | CONTINUOUS | GAS AND LIQUID HYDROCARBON | 60 | CONTINUOUS | 446 | 445 | No | -- | -- | Annual Test. 64 PSI continuous gas and fluid blew down to 60 PSI in 30 minutes, ~10 gallons muddy oil total fluid. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy. |
403901264 | Form 17 | 8/16/2024 | 8/26/2024 | | 57 | CONTINUOUS | LIQUID HYDROCARBON | 0 | NO FLOW | 485 | 484 | No | -- | -- | Engineering Ad Hoc test. 57 PSI blew down to 0 PSI within five minutes of test. No pressure or flow observed for the remainder of the test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly. |
Click for Specifics | Full | 12/8/2023 | 12/11/2023 | Plunger Lift | 22 | Down to Zero | -- | 0 | No Flow | 553 | 558 | No | No | No | Annual Test. 22 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy. |
403100628 | Form 17 | 7/7/2022 | 7/11/2022 | FLOWING | 16 | DOWN TO 0 | GAS | 0 | NO FLOW | 1991 | 1991 | No | -- | -- | Test after DOFP. Gaseous on open for 45 seconds and died. No flow for remainder of test. |
402922099 | Form 17 | 1/9/2022 | 1/10/2022 | SHUT-IN | 0 | NO FLOW | NONE | 0 | NO FLOW | 0 | 0 | No | -- | -- | Test prior to toe prep/frac. Vacuum on open for 20 seconds. |