404008920 | Form 17 | 11/25/2024 | 11/26/2024 | PLUNGER LIFT | 99 | CONTINUOUS | LIQUID HYDROCARBON | 0 | CONTINUOUS | 759 | 754 | No | -- | -- | Remediation follow up test. 99 PSI flow blew down to 0 PSI within thirty minutes. Liquid hydrocarbons observed throughout entire test. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy |
403853808 | Form 17 | 6/28/2024 | 7/15/2024 | PLUNGER LIFT | 20 | CONTINUOUS | WATER AND GAS | 10 | CONTINUOUS | 797 | 797 | No | -- | -- | Annual test. 20 PSI continuous water and gas flow blew down to 10 PSI in 30 minutes, ~5 gallons total fluid. PDC will monitor pressure and re-test according to bradenhead policy. |
403444746 | Form 17 | 6/22/2023 | 6/26/2023 | FLOWING | 37 | CONTINUOUS | GAS AND LIQUID HYDROCARBON | 0 | CONTINUOUS | 1043 | 1043 | No | -- | -- | Abatement system follow up test. 37 PSI gas and fluid flow blew down to 0 PSI within first minute of test. Fluid trickled for 8 minutes, then dripped for remainder of test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly. |
403150708 | Form 17 | 8/29/2022 | 8/30/2022 | FLOWING | 68 | CONTINUOUS | GAS | 0 | NO FLOW | 1502 | 1502 | No | -- | -- | Engineering Ad Hoc test, 65 PSI gas flow blew down to 0 PSI within 5 minutes with no flow or pressure for the remainder of the test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
|
403029160 | Form 17 | 4/20/2022 | 4/27/2022 | FLOWING | 32 | DOWN TO 0 | GAS | 0 | NO FLOW | 1951 | 1951 | No | -- | -- | Re-test, build up since 2/16/2022.
Gas for 5 seconds at open then died. |
402900163 | Form 17 | 12/6/2021 | 12/15/2021 | FLOWING | 55 | DOWN TO 0 | GAS | 0 | NO FLOW | 2172 | 2173 | No | -- | -- | Test after date of first production. Gas at open for 3 seconds then dead. Unable to sample gas. |
402697891 | Form 17 | 5/12/2021 | 5/22/2021 | SHUT-IN | 0 | NO FLOW | NONE | 0 | NO FLOW | 0 | 0 | No | -- | -- | Test prior to toe prep/frac. Vacuum on open for 1 minute and 20 seconds. |