WELL05-001-09908Ivey LC
02-036HC
PDC ENERGY INC
69175
PA
4/14/2025
WATTENBERG
90750
ADAMS  001
SWSE 11 1S68W 6
442411
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 2027 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404127465Form 173/3/20253/13/2025SHUT-IN0NO FLOW NONE0 NO FLOW 00No----Pre-P&A. 0 PSI, with no flow observed for 30 minutes.
403846188Form 176/28/20247/5/2024 55CONTINUOUS WATER AND GAS55 CONTINUOUS 525525No----Annual Test. 55 PSI continuous water and gas, did not blow down. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
403618469Form 1712/6/202312/7/2023PLUNGER LIFT175CONTINUOUS WATER AND GAS0 CONTINUOUS 563562No----Abatement system follow up test. 175 PSI water and gas flow blew down to 0 PSI within first 5 minutes of test. ~4 gallons of fluid at open turned to light trickle for remainder of test, ~5 gallons total. PDC will monitor pressure and re-test according to bradenhead policy.
403444719Form 176/22/20236/26/2023PLUNGER LIFT113CONTINUOUS WATER AND GAS0 DOWN TO 0 645642No----Abatement system follow up test. 113 PSI gas and fluid flow blew down to 0 PSI within first minute of test. Fluid trickled for 12 minutes, then dripped for remainder of test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
403150758Form 178/29/20228/30/2022FLOWING99DOWN TO 0 GAS0 NO FLOW 948948Yes----Engineering Ad Hoc test, 99 PSI gas flow blew down to 0 PSI in five minutes. No flow or pressure for the remainder of the test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
403074820Form 176/1/20226/10/2022FLOWING72DOWN TO 0 GAS0 NO FLOW 11951194No----Test after pressure discovery. Gaseous on open for 10 seconds and died. Unable to collect gas sample due to lack of volume. No flow for remainder of test.
402833112Form 1710/5/202110/6/2021FLOWING42DOWN TO 0 GAS0 NO FLOW 23182318No----Test after DOFP. Gas on open for 2 minutes and died. No flow for remainder of test.
402697904Form 175/12/20215/22/2021SHUT-IN0NO FLOW NONE0 NO FLOW 00No----Test prior to toe prep/frac. Vacuum on open for 2 minutes.