View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404210721Form 175/5/20255/20/2025GAS LIFT63CONTINUOUS WATER AND GAS1 WHISPER 266266No----Engineering Ad Hoc test. 63 PSI water and gas blew down to 1 PSI in thirty minutes. Whisper water observed for entire test, ~1 gal. Operator will schedule a sampling event and submit results via form 43. Operator will continue to monitor monthly.
403846203Form 176/28/20247/5/2024 70CONTINUOUS WATER AND GAS68 CONTINUOUS 342341No----Annual Test. 70 PSI water and gas, blew down to 68 PSI in thirty minutes. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
403618511Form 1712/6/202312/7/2023PLUNGER LIFT124CONTINUOUS GAS AND LIQUID HYDROCARBON0 NO FLOW 415418No----Abatement system follow up test. 124 PSI fluid and gas flow blew down to 0 PSI within first 3 minutes of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403444743Form 176/22/20236/26/2023PLUNGER LIFT61CONTINUOUS GAS AND LIQUID HYDROCARBON0 NO FLOW 495495No----Abatement system follow up test. 61 PSI gas and fluid flow blew down to 0 PSI within first minute of test. Fluid trickled for 7 minutes, then dripped for remainder of test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
Click for SpecificsFull8/29/20229/6/2022 37Down to Zero--0Down to Zero853852NoNoneNone 
402900040Form 1712/6/202112/15/2021FLOWING49DOWN TO 0 GAS0 NO FLOW 24282427No----Test after date of first production. Gas at open for 5 seconds then dead.
402679610Form 174/29/20215/4/2021SHUT-IN--NO FLOW NONE0 NO FLOW 00No----Test prior to toe-prep/frac. Vacuum on open, died in 1 minute and 30 seconds.