| 403332272 | Form 17 | 2/27/2023 | 2/28/2023 | SHUT-IN | 70 | CONTINUOUS | GAS | 0 | NO FLOW | 400 | 400 | Yes | -- | -- | Pre-P&A. 70 PSI gas flow blew down to 0 PSI within 10 minutes. No pressure or flow observed for the remainder of the test. PDC will schedule a sampling event and submit results via form 43. |
| 403110188 | Form 17 | 7/11/2022 | 7/19/2022 | SHUT-IN | 52 | DOWN TO 0 | GAS | 0 | NO FLOW | 360 | 360 | Yes | Yes | -- | Test after pressure discovery. Gas on open, collected BH and production sample. Down to 0 PSI in 40 seconds. Whisper for 2 minutes and died. No flow for remainder of test. |
| 402754112 | Form 17 | 7/15/2021 | 7/20/2021 | SHUT-IN | 0 | WHISPER | GAS | 0 | NO FLOW | 320 | 320 | No | -- | -- | Test per NTO. Whisper on open for 2 minutes and died. No flow for remainder of test. |
| Click for Specifics | Light | 8/28/2020 | 9/7/2020 | | 7 | | -- | 0 | No Flow | 324 | 324 | No | No | No | |
| 402163181 | Form 17 | 8/30/2019 | 8/31/2019 | FLOWING | 20 | DOWN TO 0 | -- | 0 | NO FLOW | 320 | 320 | No | -- | -- | Test per NTO. BH had 20 psi on open. Blew dead in < 1 minute. BH dead |