| 403284409 | Form 17 | 1/9/2023 | 1/10/2023 | SHUT-IN | 24 | DOWN TO 0 | WATER AND GAS | 0 | CONTINUOUS | 0 | 0 | Yes | -- | -- | Pre-P&A. 24 PSI gas and water flow blew down to 0 PSI within first few seconds of test. Water trickled constantly for entire test. PDC will schedule a sampling event and submit results via form 43. |
| 403024258 | Form 17 | 4/13/2022 | 4/22/2022 | SHUT-IN | 33 | DOWN TO 0 | WATER H20 | 0 | CONTINUOUS | 240 | 240 | Yes | -- | Yes | Re-test, Water on open, collected 1000 mL sample. Flow died to trickle after sample, Intermittent water at 8 minute mark for remainder of test. Produced ~ 2.75 gallons of water total. |
| 402754109 | Form 17 | 7/15/2021 | 7/20/2021 | SHUT-IN | 29 | DOWN TO 0 | GAS | 0 | SURGE | 220 | 230 | Yes | -- | Yes | Test per NTO. Gas on open for 2 seconds then surged water. Collected 1000 mL water sample, produced ~ 4 gallons total. |
| Click for Specifics | Light | 8/28/2020 | 9/7/2020 | | 44 | | -- | 0 | No Flow | 210 | 223 | No | No | No | |
| 402163179 | Form 17 | 8/29/2019 | 8/31/2019 | FLOWING | 45 | DOWN TO 0 | -- | 0 | NO FLOW | 240 | 250 | No | -- | -- | Test per NTO. BH had 45 psi on open. Blew dead in < 10 seconds. BH dead. |