Skip to Main Content

COGIS

Facility Detail

COGIS - WELL SCOUT CARD

Click image to view related facilities. Related  Click image to view inspection information. InspClick image to view MIT information. MITClick image to access interactive map at well/facility location. GISClick image to view imaged documents for this well/facility. DocClick image to view imaged documents for this well/facility. COAClick image to view wellbore completion diagram. WellboreClick image to search for orders within this facility's section. OrdersClick image to view bradenhead scoutcard data. Bradenhead
 Surface Location
 API# 05-001-08233
Well Classification: GW Status: PA - 12/18/2019
Well Name/No:CHAMPLIN 117 AMOCO I #2
(Click Well Name for Production Data)
Click Here for Transporter Gatherer Info
Operator:KP KAUFFMAN COMPANY INC - 46290
(Click Operator Name for Company Detail Report)
Federal Or State Lease #:
Facility Status:PAStatus Date12/18/2019
FacilityID:202828LocationID:320151
Municipality/County:COMMERCE CITY / ADAMS #001Location:NWSE 21 2S66W 6
Field:HOLSTER - #36600Elevation:5225 ft.
Basin:DENVER (DJ) BASIN  
Planned Location:2040FSL  2040 FELLat/Long: 39.861881 / -104.779277Lat/Long Source: Calculated From Footages
As Drilled Location:Footages Not AvailableLat/Long: 39.861990 / -104.779160Lat/Long Source: Field Measured
 Wellbore And Formation Details -- select either a wellbore Or formation to expand.
 

Wellbore #00             Wellbore Classification: GW             Status: PA - 12/18/2019             Measured TD: 8535 ft.    Vertical TD: 0 ft.

 Wellbore Data for Original WellboreWellbore Classification: GW        PA - 12/18/2019
Wellbore Permit
Permit #:19822009 Expiration Date:4/8/1983
Proposed Depth/Form:8500 ft.
Surface Mineral Owner Same:Not available
Mineral Owner:FEESurface Owner:Not available
Unit: Unit Number: 
Formation And Spacing:Code: JSND , Formation: J SAND , Order: 0 , Unit Acreage: , Drill Unit:

Wellbore Completed
Completion Date:2/28/1982
Spud Date:11/23/1982Spud Date Is:ACTUAL
Measured TD:8535 ft.Measured PB depth:8435 ft.
True Vertical TD:0 ft.True Vertical PB depth:
Log Types:SP-IES FDC-GR CALIPER LOG
Casing:String Type: SURF, Hole Size: 12.25 in., Size: 9.625 in., Top: 0 ft., Depth: 1675 ft., Weight: 40 , Citings Type: ACTUAL
Cement:Sacks: 1100, Top: 0 ft., Bottom: 1675 ft., Determination Method: VISU
Casing:String Type: 1ST, Hole Size: 7.875 in., Size: 5.5 in., Top: 0 ft., Depth: 8535 ft., Weight: 17 , Citings Type: ACTUAL
Cement:Sacks: 320, Top: 6688 ft., Bottom: 8535 ft., Determination Method: CBL
FormationInterval TopLog BottomCoredDSTs
FOX HILLS0 ft.
SUSSEX5070 ft.
NIOBRARA7558 ft.
FORT HAYS7916 ft.
CODELL7946 ft.
D SAND8320 ft.
J SAND8356 ft.

Formation JSND                     Formation Classification:  GW                     Status:  AB - 12/18/2019                Interval Top: 8368 ft.    Interval Bottom: 8412 ft.

 Completed Information for Formation J SAND
1st Production Date:2/18/1983Choke Size:1.000 in.
Formation Name:J SANDCommingled:
Production Method:PUMPING
Open Hole Completion:
Formation Treatment
Treatment Date:2/28/1982
Treatment Summary:SEE DOCUMENT # 360505
Tubing Size:2.875 in.Tubing Setting Depth:8438 ft.
Tubing Packer Depth:Tubing Multiple Packer:
Open Hole Top:Open Hole Bottom:
Initial Test Data:
Test Date:2/28/1983Test Method:PUMPING
Hours Tested:24Gas Type:
Gas Disposal:SOLD
Test TypeMeasure
BBLS_H2O 8
BBLS_OIL 3.3
CALC_BBLS_H2O 8
CALC_BBLS_OIL 3.3
CALC_GOR 3636
CALC_MCF_GAS 12
GRAVITY_OIL 51.2
MCF_GAS 12
Perforation Data:
Interval Top:8368 ft.# Of Holes:
Interval Bottom:8412 ft.Hole Size:
Primary Well Designation:
None      i
            All DesignationsDate
Reported PluggedY12/18/2019
Out Of Service RepurposedN 
Out Of ServiceN 
Inactive ExceptionN 
Noticed InactiveN 
Defined InactiveN 
Low ProducingN 

BOE/MCFE/GOR Calculations
Production for Previous 12 Months
November 2024 - October 2025i
Total Oil Produced (Barrels)0
Total Gas Produced (MCF)0
GOR
GOR DeterminationMCFE
Average BOE per Day0.000
Average MCFE per Day0.000

 Federal Financial Assurance  i 

 Tribal Well  i No